HVAC Services for Telecom and Data Centers

Ultimate for uptime


Bard

FUSION-TEC (WR35BP - WR58BP) has been designed specifically to optimize Free Direct Ambient Cooling (DAC) opportunities. By implementing a reverse-airflow design, productive outdoor air for free cooling is brought into the system from the lower portion of the chassis. The heat in the shelter is exhausted out of the top of the chassis which completely eliminates any possibility of recirculating hot exhaust into the cool air entryway. When outdoor air is not productive for free cooling, the FUSION-TEC system has a fully flexible mechanical cooling operation that operates at an IPLV of up to 17.0, and also satisfies the D.O.E.'s future 11.0 EER efficiency requirements.

MULTI-TEC Wall-Mount Air Conditioner (W18ABP-W72ACBP W18LBP-W36LBP) Utilize PLC technology to allow multiple units to operate connected to a single LC6000 controller. When installed with an optional 100% free cooling economizer, the unit will supply full-rated airflow in free cooling mode with the ability to exhaust unconditioned indoor air without the need for additional relief openings in the structure.

MEGA-TEC (W090AP - W180BP) is designed for applications requiring a large amount of sensible cooling capacity and limited wall space. Dual refrigeration circuits and a total of three stages with the lowest stage less than 35% of the total capacity provide cooling for an area with a varying heat load. MEGA-TEC provides an AHRI certified 10+ EER solution that meets D.O.E. requirements and the efficiency ratings of state and national codes. Industrial grade indoor and outdoor fans provide years of trouble-free service. An optional economizer provides full-flow outdoor air intake and room exhaust based on outside temperature or enthalpy.

HVAC - TELECOM

We can also supply CommStat 3, CommStat 4 and CommStat 6 thermostats and controllers.

The External Low Noise Blower (ELNB) is a field installed condenser air hood and blower that can reduce the sound levels of air conditioners by up to 6 dbA.

Bard

INVISIBLE COMFORT The Bard I-TEC units blend into classroom settings with several high quality color options or graphic covers and increase usable school square footage by eliminating equipment rooms. The exterior mounted units provide the same quality, dependability and quiet operation from outside the classroom. We work with architects to fit the design within budget constraints by eliminating piping, duct-work, and fire dampers while significantly reducing installation time.

PRECISION COMFORT Bard's precision systems can be designed for the needs of each classroom while eliminating costly and complicated central systems. Bard comfort systems provide ventilation, temperature and humidity control with high efficiency and quiet operation. Bard systems include highly efficient ECM indoor blower motors, and most applications can accept MERV 13 filters, recommended for added filtration of virus sized particles. A stand-alone, DDC-compatible commercial controls platform is available with customized operation within pre-set parameters established by the school’s maintenance director.

Marvair For over a half a century, Marvair® has been designing and manufacturing heating, cooling, and ventilating products specifically for schools throughout the country. From the beginning, we have manufactured products that have met the ever-changing requirements and needs of the classroom. All Marvair heat pumps and air conditioners are self-contained packaged systems. No expensive refrigeration work is required in the field. Also, each unit is run and tested at the factory, minimizing the possibility of field problems.

HVAC - EDUCATION

Individual classroom units mean superior comfort and energy savings. Select Marvair units provide the flexibility of part-load cooling and heating and redundancy by design. When a central chiller/boiler system fails, an entire wing or school is affected. If a Marvair unit needs service, only one classroom is affected. When only a portion of the wing or school is being used, a large chiller/boiler system may have to operate the chiller at a reduced part load condition, the boiler for reheat and a large air handler. With the Marvair packaged unit, only the classroom or office being used is conditioned.

Marvair is at the forefront in designing units for quieter classrooms.Whenever you see "Quiet Zone", it is an indication that the units were designed with quiet operation as a high priority.

Marvair MAA and 8AA wall mounted heat pumps and air conditioners are some of the most economical ways to heat, cool, and ventilate site built or modular classrooms. These exterior mounted units are built in a variety of styles and configurations.

The Scholar series of heat pumps and air conditioners are designed to provide quiet, efficient cooling, heating and ventilation for classrooms in a single package. These air source units are our new Scholar 2.0 featuring a variable speed compress and a module design ease installation. Scholar units are installed inside the classroom against an exterior wall. The vertical configuration minimizes the floor space occupied by the HVAC unit. To meet fresh air requirements, a full range of ventilation options are available, including the Marvair GreenCube Energy Recovery Ventilator. All service and maintenance can be performed while the unit is in the classroom; sliding the unit away from the wall is not required. The Scholar units can be controlled by a wall mounted thermostat or interfaced with an energy management system.

The GAA Series of wall mounted air conditioners are built for operation with either natural or LP gas heat. These units are available with a complete range of ventilation options and are ideal for cold climates.

Thermostats and Controllers for Classrooms

Marvair offers a wide variety of thermostats for control of our heat pumps and air conditioners. All of our thermostats are digital - no mercury bulbs - are reliable, have easy to read LCD displays and are easy to operate. Programmable and non-programmable thermostats are offered with auto or manual changeover and 1 or 2 stage heating and cooling.

Dehumidification

Outside air brought in to meet ventilation requirements can also raise the humidity to unacceptable levels. Keeping the humidity at acceptable levels is critical for comfort and control of potentially toxic mold and mildew. Marvair offers various solutions to controlling humidity.

The GreenCube ERV, is a total energy recovery ventilator. In the summer, both heat and humidity is stripped from the incoming air before it is introduced into the classroom.

Hot Gas Reheat Coil (HGR) When high humidity levels coincide with mild outdoor temperatures, e.g., a rainy spring day, active dehumidification is required to control humidity levels in the classroom. The HGR coil is a factory installed option that can dehumidify classroom without overcooling . For areas of the country where humidity is a year round concern, two HGR coils can be used in selected Marvair units to provide additional dehumidification.

Electric Reheat Electric reheat achieves the same purpose as the HGR coil, but the electric strip heaters are used to heat the air stream.

Ventilation

Proper ventilation with outside air is essential for good indoor air quality. To address the ASHRAE ventilation requirements, Marvair heat pumps and air conditioners are available with a number of ventilation options to best suit your climate and budget requirements.

PowerVent with motorized damper plus powered exhaust of inside air can provide up to 450 CFM of outside air. Separate speed control of the intake and exhaust air movers allows positive pressurization of the classroom.

Motorized fresh air damper provides up to 450 CFM of outside air with pressure relief.

Manual damper with pressure relief provides up to 450 CFM of outside air.

Demand Control Ventilation

When the GreenCube ERV or any of the motorized damper ventilation options are specified, a CO2 sensor can be used to control operation. The CO2 sensor activates the ventilation system based upon carbon dioxide levels in the classroom. This can significantly reduce the amount of outside air introduced into the classroom and save on operating costs.

Bard

CLIMATE CONTROL SOLUTIONS SPECIFICALLY DESIGNED FOR DATA CENTERS
WHEN PRECISE CLIMATE CONTROL MATTERS. Bard Manufacturing provides tight temperature and humidity regulation specifically designed for data center cooling. Our systems improve Power Usage Effectiveness (PUE) for economical, effective climate control for data centers by creating an ideal environment for equipment longevity.

SPACE-SAVING EQUIPMENT
Every square inch counts when it comes to server storage. Bard’s equipment doesn’t take up extra space with ducting and large, bulky in-room units. Our modular approach to installation means you select the right units for your space which can be placed in easily-accessible locations on the outside of walls, allowing more usable floor space for revenue-generating data center equipment.

PROTECT YOUR UPS
An Uninterruptible Power Supply (UPS) unit is critical for data centers to keep power running in an outage. Bard’s wall-mounted HVAC units protect UPS systems and buildings from overheating, particularly in mission-critical scenarios, by controlling climate with precision.

HVAC - EDUCATION
Marvair

Marvair produces a wide range of air conditioners and heat pumps which are suitable for a variety of industrial applications.

E-Houses

Prefabricated walk-in modular outdoor structures, often referred to as an “Electrical House�?, or E-House, are designed to house medium and low voltage switchgear and auxiliary equipment. This type of modular, portable, building is growing in popularity, and Marvair offers perfectly sized HVAC solutions.

Marvair MAA and 8AA wall mounted heat pumps and air conditioners are some of the most economical ways to heat, cool, and ventilate site built or modular classrooms. These exterior mounted units are built in a variety of styles and configurations.

The Scholar series of heat pumps and air conditioners are designed to provide quiet, efficient cooling, heating and ventilation for classrooms in a single package. These air source units are our new Scholar 2.0 featuring a variable speed compress and a module design ease installation. Scholar units are installed inside the classroom against an exterior wall. The vertical configuration minimizes the floor space occupied by the HVAC unit. To meet fresh air requirements, a full range of ventilation options are available, including the Marvair GreenCube Energy Recovery Ventilator. All service and maintenance can be performed while the unit is in the classroom; sliding the unit away from the wall is not required. The Scholar units can be controlled by a wall mounted thermostat or interfaced with an energy management system.

The GAA Series of wall mounted air conditioners are built for operation with either natural or LP gas heat. These units are available with a complete range of ventilation options and are ideal for cold climates.

Thermostats and Controllers for Classrooms

Marvair offers a wide variety of thermostats for control of our heat pumps and air conditioners. All of our thermostats are digital - no mercury bulbs - are reliable, have easy to read LCD displays and are easy to operate. Programmable and non-programmable thermostats are offered with auto or manual changeover and 1 or 2 stage heating and cooling.

Dehumidification

Outside air brought in to meet ventilation requirements can also raise the humidity to unacceptable levels. Keeping the humidity at acceptable levels is critical for comfort and control of potentially toxic mold and mildew. Marvair offers various solutions to controlling humidity.

The GreenCube ERV, is a total energy recovery ventilator. In the summer, both heat and humidity is stripped from the incoming air before it is introduced into the classroom.

Hot Gas Reheat Coil (HGR) When high humidity levels coincide with mild outdoor temperatures, e.g., a rainy spring day, active dehumidification is required to control humidity levels in the classroom. The HGR coil is a factory installed option that can dehumidify classroom without overcooling . For areas of the country where humidity is a year round concern, two HGR coils can be used in selected Marvair units to provide additional dehumidification.

Electric Reheat Electric reheat achieves the same purpose as the HGR coil, but the electric strip heaters are used to heat the air stream.

Ventilation

Proper ventilation with outside air is essential for good indoor air quality. To address the ASHRAE ventilation requirements, Marvair heat pumps and air conditioners are available with a number of ventilation options to best suit your climate and budget requirements.

PowerVent with motorized damper plus powered exhaust of inside air can provide up to 450 CFM of outside air. Separate speed control of the intake and exhaust air movers allows positive pressurization of the classroom.

Motorized fresh air damper provides up to 450 CFM of outside air with pressure relief.

Manual damper with pressure relief provides up to 450 CFM of outside air.

Demand Control Ventilation

When the GreenCube ERV or any of the motorized damper ventilation options are specified, a CO2 sensor can be used to control operation. The CO2 sensor activates the ventilation system based upon carbon dioxide levels in the classroom. This can significantly reduce the amount of outside air introduced into the classroom and save on operating costs.